BWRBG - 520 ADHESIVE

Product Identification

Product ID:520 ADHESIVE
MSDS Date:03/19/1993
FSC:8040
NIIN:00-826-2936
MSDS Number: BWRBG

Responsible Party
ARMSTRONG WORLD INDUSTRIES INC
313 W LIBERTY ST
LANCASTER, PA 17604
US

Emergency Phone: 800-255-3924

Info Phone: 717-396-2328

Cage: 03938

Contractor
ARMSTRONG WORLD INDUSTRIES, INC.
3209 LANCASTER, PA 17604 US

Telephone: 717-396-2328; 717-396-2935

Cage: 03938

Ingredients

ACETONE (SARA 313) (CERCLA)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 25%

OSHA PEL 1000 PPM

ACGIH TLV: 750 PPM/1000 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 16%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: S, 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


HEXANE (CERCLA)

CAS: 110-54-3

RTECS: MN9275000

Fraction By Weight: 34%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


1,3-BUTADIENE, 2-CHLORO-, POLYMERS; (SYNTHETIC RUBBER)

CAS: 9010-98-4

RTECS: EI9460000

Fraction By Weight: 13%

OSHA PEL N/K

ACGIH TLV: N/K


PHENOLIC RESIN

Fraction By Weight: 9%

OSHA PEL N/K

ACGIH TLV: N/K


RUBBER CURING INGREDIENTS

Fraction By Weight: 3%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TOLUENE APPEARS ON THE NAVY LISTING OF
OCCUP CHEM REPROD HAZARDS. SEEK CONSULTATION FROM APPROP HLTH
PROFESSIONALS CONCERNING LATEST HAZARD LIST INFO & SAFE HNDLG &
EXPOS INFO . ACUTE:EXCESSIVE SKIN CONT MAY CAUSE DRYING & CRACKING
OF SKIN, & RSLT IN DERM. CONT W/EYES WILL CAUSE IRRIT. (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:INHAL:IRRIT OF RESP TRACT, COUGHING,
HEADACHE, DIZZINESS, DROWSINESS, NAUSEA; UNCOORDINATED MOVEMENTS.
Medical Cond Aggravated by Exposure:ANY CONDITION GENERALLY AGGRAVATED
BY SOLVENTS; PREEXISTING UPPER RESPIRATORY & LUNG DISEASE SUCH AS,
BUT NOT LIMITED TO BRONCHITIS, EMPHYSEMA, AND ASTHMA.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . SKIN & EYES:FLUSH WITH PLENTY OF
WATER FOR @ LEAST 15 MINUTES. ADDITIONALLY WITH SKIN CONT, WASH
W/SOAP & WATER. REFER TO PHYS IF IRRIT OR SYMPTOMS PERSIST.
INHAL:RE MOVE TO FRESH AIR IF EXPOSED TO EXCESS CONC OF VAPOR. SEEK
MED ATTN IF SYMPTOMS PERSIST.

Fire Fighting

Flash Point Method:PMCC
Flash Point:<20F,<-7C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, HALON.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CNTNRS IN FIRE MAY RUPTURE DUE TO
PRESS BUILD-UP; USE WATER TO COOL CNTNRS TO PREVENT THIS.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. VENTILATE AREA OF
SPILL/LEAK; IF USING MECH VENT, MAKE SURE THAT IT IS EXPLO-PROOF OR
DOES NOT PRESENT IGNIT SOURCE. FOR EXPOS ABOVE TLV, WEAR APPRVD
RESP EQUIP. CONTAIN S PILL, PREVENTING IT FROM ENTERING
SEWER(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN AREA SUITABLE FOR FLAM
MIXTURES. REC STOR TEMP IS BELOW 90 DEGREES F. VAPS ARE FLAM & ARE
HVR/AIR.
Other Precautions:PROHIBIT SMOKING & ELIM ALL OTHER SOURCES OF IGNIT,
SUCH AS REGULAR ELEC TOOLS & APPLIANCES, MAKING SURE THAT PILOTS ON
GAS-FIRED WATER HEATERS ARE EXTINGUISHED. WARNING:PROD CONTAINS
TOLUENE, CHEM KN OWN TO ST OF CA TO CAUSE (SUPDAT)

Exposure Controls

Respiratory Protection:WITH ADEQ VENT, NIOSH/MSHA RESP EQUIP SHOULD NOT
BE NEEDED. IF ADEQ VENT IS NOT AFFORDED, WEAR NIOSH/MSHA RESP EQUIP
APPRVD FOR ORGANIC VAPORS.
Ventilation:USE NATURAL CROSS-VENT, LOCAL (MECHANICAL) PICK-UP, AND/OR
GEN AREA (MECH)VENT TO PVNT AN ACCUM OF SOLV VAPS, (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL RELEASE:LINES/WATERWAYS. USE ABSORB TO ASSIST W/PICK-UP OF MATL.
SCRAPE UP ADHESIVE & PLACE IN CNTNR. OTHER PRECAUT:BIRTH
DEFECTS/OTHER REPROD HARM. VENT:FROM LOWER LEV OF WORK SPACES. VENT
SHOU LD BE SUFFICIENT TO KEEP SOLV VAP CONC BELOW TLV.

Chemical Properties

Boiling Pt:B.P. Text:>152F,>67C
Spec Gravity:0.83 (H*2O=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NEGLIGIBLE
Appearance and Odor:STRAW COLORED LIQUID WITH CHARACTERISTIC SOLVENT
ODOR
Percent Volatiles by Volume:75(WT)

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE, AND
OTHER TOX VAPS & GASES THAT ARE COMMON TO THERMAL DEGRADATION OF
ORG CMPDS.

Disposal

Waste Disposal Methods:INCIN/OTHER METHOD APPROVED FOR IGNITIBLE WASTES
I/A/W FEDERAL, STATE, AND LOCAL REGULATIONS. THIS PROD CONTAINS
CHEM SUBJECT TO REPORTING REQUIREMENTS OF 313 OF TITLE III OF
SUPERFUND AMENDMENT & REA UTHORIZATION ACT OF 1986 & 40 CFR PART
372.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.